Art.-No. 530354

fischer TermoZ SV II Ecotwist 10-30

The advantages / Product description

The innovative countersinkable ETICS fixing for all building material classes
Advantages
  • Standard anchoring depth for all building materials.
  • One fixing for all insulating material thicknesses from 100 mm to 400 mm. This increases productivity, saves time and storage space.
  • Sturdy setting tool with stop disc for a simple and precise setting procedure.
  • The screw disc cuts in cleanly, without damaging the insulating material.
  • Simple setting using the specially designed setting tool.
The fischer TermoZ SV II EcoTwist is ideal for fixing pressure-resistant insulation from 100 to 400 mm thick for thermal insulation systems such as polystyrene boards or homogeneous mineral wool boards in concrete, solid and perforated brick, lightweight aggregate concrete and aerated concrete securely. The European Technical Assessment guarantees a secure hold. The screw fixing comprises a grey plug sleeve with attached disc and a screw. The TermoZ SV II EcoTwist is set very deep quickly and accurately. The insulation disc is gently screwed into the fixing as it rotates. The uniform anchorage depth for all building materials and the universal size for all insulation thicknesses reduces the complexity, saves time and storage space.

Application and approval

Applications
  • Attachment of ETICS EPS insulation and homogeneous mineral wool boards to concrete and masonry building materials
  • Counterbored installation
Building materials
  • Building material classes A, B, C, D, E
  • Concrete
  • Concrete (weather shell)
  • Building brick
  • Solid sand-lime brick
  • Hollow blocks made from lightweight concrete
  • Vertically perforated brick
  • Perforated sand-lime brick
  • Aerated concrete
  • Lightweight aggregate concrete
  • Sepa Parpaing (French brick)
You can find detailed information on building materials in the registration document.
Approvals
  • ETA-12/0208
  • DoP No. 0324
  • EPD-FIW-20210314-CBD1-EN

Assembly instruction

Functionality
  • The plug is inserted through the insulation in the drill hole and rotated with the setting tool.
  • The screw-mounted support plate and the screw have the same pitch. As a result, they rotate through the insulation simultaneously until the anti-rotation lock reaches the subsurface.
  • The steel screw then rotates into the expansion zone. At the same time, the compression zone is pushed together to a few millimetres and the fixing anchors in the subsurface.
  • The setting procedure ends when the marking ring lies on the insulation.
  • For bridging non-supporting layers.
Mounting Strip 1 Picture
1 / 7

Technical data

ETA-approval
Insulation thickness (
hD
)
100 - 400 mm
Disc ø 66 mm
Drill diameter (
d0
)
8 mm
Thickness of tolerance compensation non-bearing layers (
ttol
)
10 - 30 mm
Effect. anchorage depth (
hef
)
35 mm
Min. drill hole depth in the building material incl. non-bearing layers (
h1
)
75 mm
Min. total drill hole incl. insulation and non-bearing layers (
h
)
hD + 75 mm
Packaging Folding box
Amount 100 pcs.
GTIN (EAN-Code) 4048962202656

Documents for download

  • ETAs and DoPs
  • Sustainability
  • Technical documents
  • Sales materials
European Technical Assessment for fischer TermoZ SV II Ecotwist - Screwed-in plastic anchor for fixing of external thermal insulation composite systems with rendering in concrete and masonry
Created on 10/18/2022
Declaration of Performance for termoz SV II ecotwist (Plastic anchors for use in concrete and masonry)
Created on 10/31/2022
cd-green-58bb58464c-tb9pl